Version v12r5
Release Date 2 December 2004 Description
Backward-compatible development version. Based on Gaudi v15r5 and LHCb v16r4. Includes LoKi v3r6.
New version with some modifications and many additions. All changes that could interfere with the stripping but were not needed appear in this version.
Also there are many new features to allow the development of the HLT.
Main modifications Physics:
l
oadTools()has been made private inDVAlgorithm. Remove all instances in your private code.New
KFFitTooldoing vertex fits allowing usage of photons, constraints on intermediate resonances...Bug fix in the
ParabolicTransporter.Updated
DaVinciEffpackage. See the documentation note.The
DebugToolnow uses standard units (configurable by options).
LoKiv3r6Trigger:
New
Hlt/HltGeneric, the L1-confirmation algorithm for the HLTBug fix in Trg sequence
New
RichHltSyswith several other packages allowing to use RICH in the HLT.The
TrgParticleMakernow can use Calo and RICH.
LoKiHltv2r0New platform (copied from Marco's mail to lhcb)
A new version of linux, scientific linux CERN 3 (slc3), has been deployed at CERN. All DaVinci versions starting from v12r3 are compiled for this platform too. We strongly recommend to lxplus users to move to SLC3 at your earliest convenience. You can login to the CERN SLC3 cluster using the alias lxslc3 (i.e. ssh lxslc3 instead of ssh lxplus). Note that currently the slc3 machines are rather empty, so you should gain by making the move early.
The lxplus alias will be changed to point to the lxslc3 cluster early in January. Redhat7.3 will continue to be accessible via the lxplus7 alias for some time after that, but the capacity will be reduced rather rapidly.
The LHCb software will from now on be released for slc3 in both optimised and debug builds. We will continue to provide optimised binaries for rh73 for as long as there is demand.
Please report any problem.
Known problems: Troubles with RFIO: Crashes in PoolRootTreeEvtCnvSvc. Try to use the following trick, which seems to work fine:
- Copy the file
/afs/cern.ch/user/p/pkoppenb/public/.rootauthrcto your home directory
- Make sure there is no
.rootrcfile there, or at least that you know what it is doing.- Replace all the "
rfio:" by "castor:" in your input data. It will look likeEventSelector.Input = {
"DATAFILE='PFN:castor:/castor/cern.ch/lhcb/DC04/00000541_00000665_9.dst'
TYP='POOL_ROOTTREE' OPT='READ'"};
This will pick up rootd instead of rfio.Documentation Doxygen Release notes (for detailed release notes of each packages look in the release area) Requirements Installation follow the LHCb installation procedure tar files of the sources web access to CVS repository web access to AFS release area DaVinci packages modified with respect to v12r4
Phys/DaVinciv12r52004-12-01 Hlt/HltGenericv2r0New package L0/L0MuonKernelv2r3Bug fix L0MuonTriggerv2r2p1Use L0MuonKernelv2r3L0Checkerv3r0New properties Phys/DaVinciAssociatorsv5r2p1Remove annoying error message DaVinciEffv3r2Updated EffSelCheckDaVinciFilterv1r3New Filter tools and algorithms DaVinciKernelv2r1Small modifications DaVinciMCToolsv5r7Use standard units in DebugToolDaVinciTestv5r4Bug fix in ChargedPtotoPAnalysisDaVinciToolsv11r3Remove PreDVDaVinciTransporterv1r2Bug Fix in ParabolicTransporterVertexFitv1r2New KFFitToolPhysSel/PhysSeleSysv7r12Bd2a1Dstarv2r4Bs2MuMuv2r4p1Rich/RichHLTSysv1r0RichTrgGlobalPIDv1r0HLT global PID RichTrgLocalPIDv1r0HLT local PID RichTrgToolsv1r0Tools/LoKiv3r6LoKiHltv2r0Utilitiesv1r12Removed TriggerFilter.*Trg/TrgSysv1r1Modified options TrgToolsv6r1Updated TrgParticleMakerLHCb packages used LHCb v16r4 (refer to the requirements files for full package list and corresponding release notes for details) Gaudi packages used based on Gaudi v15r5 .